Manual: thermald
thermald(8) System Manager's Manual thermald(8)
NAME
thermald - start Linux thermal daemon
SYNOPSIS
thermald [ OPTIONS ]
DESCRIPTION
thermald is a Linux daemon used to prevent the overheating of platforms. This daemon monitors temperature and applies
compensation using available cooling methods.
By default, it monitors CPU temperature using available CPU digital temperature sensors and maintains CPU temperature
under control, before HW takes aggressive correction action.
Thermal daemon looks for thermal sensors and thermal cooling drivers in the Linux thermal sysfs (/sys/class/thermal)
and builds a list of sensors and cooling drivers. Each of the thermal sensors can optionally be binded to a cooling
driver by the in kernel drivers. In this case the Linux kernel thermal core can directly take actions based on the
temperature trip points, for each sensor and associated cooling device. For example a trip temperature X in a sensor
can be associates a cooling driver Y. So when the sensor temperature = X, the cooling driver "Y" is activated.
Thermal daemon allows one to change this relationship or add new one via a thermal configuration file (thermal-
conf.xml). This file is automatically created (thermal-conf.xml.auto) and used, if the platform has ACPI thermal re‐
lationship table. If not this needs to be manually configured.
For manual configuration refer to the manual page of the thermal-conf.xml.
In some newer platforms the auto creation of the config file is done by a companion tool "dptfxtract". This tool can
be downloaded from "https://github.com/intel/dptfxtract". It is suggested as parts of the install process, run dptfx‐
tract.
There can be multiple configuration files. User can select a configuration file via -config-file option to override
the default selection. The default selection picks one of the file in the following order:
- /etc/thermald/thermal-conf.xml.auto
- /var/run/thermald/thermal-conf.xml.auto
- /etc/thermald/thermal-conf.xml
(*Assuming configure prefix=/ is used during build.)
There is another companion tool "ThermalMonitor", which presents a graphical front end. This allows the monitoring of
sensors and changing of thermal trips to give the user more control. The source code of "ThermalMonitor" is a part of
the thermald github source, in the tools folder.
OPTIONS
-h, --help
Show help options.
--version
Print thermald version and exit.
--no-daemon
Don't become a daemon: Default is daemon mode.
--loglevel=info
log severity: info level and up.
--loglevel=debug
log severity: debug level and up: Max logging.
--poll-interval
Poll interval in seconds: Poll for zone temperature changes. To disable polling, set to zero. Polling can
only be disabled, if available temperature sensors can notify temperature change asynchronously.
--dbus-enable
Enable Dbus.
--exclusive-control
Act as exclusive thermal controller. This will use user-space governor for thermal sysfs and take over con‐
trol.
--ignore-cpuid-check
Ignore cpuid check for supported CPU models.
--config-file
Specify thermal-conf.xml path and ignore default thermal-conf.xml.
--ignore-default-control
Ignore default CPU temperature control. Strictly follow thermal-conf.xml or thermal-conf.xml.auto.
--workaround-enabled
Enable special workarounds for RAPL MMIO power limit and TCC offset every 30 seconds. This helps to disable
RAPL MMIO when not used and adjust TCC offset in certain Lenovo laptops.
--disable-active-power
Disable active power management. This will not set active power limits using RAPL MMIO. This may result in
constrained performance, if the system boots up with lower power limits.
--adaptive
Use DPTF adaptive tables when present. This will ignore thermald config via xml files.
--test-mode
Force use adaptive mode and exit if not supported, instead of restarting in non adaptive mode. This option is
primarily for developers.
--systemd
Assume that thermald is started by systemd. This will prevent running as daemon irrespective of --no-daemon
option.
--ignore-critical-trip
If the configuration defined a critical temperature point, which is too low, this option will avoid shutting
down the system on reaching this temperature limit.
SEE ALSO
thermal-conf.xml(5)
May 8, 2013 thermald(8)