ETHTOOL(8)					   System Manager's Manual					  ETHTOOL(8)

NAME
       ethtool - query or control network driver and hardware settings

SYNOPSIS

       ethtool devname

       ethtool -h|--help

       ethtool --version

       ethtool [--debug N] args

       ethtool [--disable-netlink] args

       ethtool [--json] args

       ethtool [-I | --include-statistics] args

       ethtool [--phy N] args

       ethtool --monitor [ command ] [ devname ]

       ethtool -a|--show-pause devname

       ethtool -A|--pause devname [autoneg on|off] [rx on|off] [tx on|off]

       ethtool -c|--show-coalesce devname

       ethtool -C|--coalesce devname [adaptive-rx on|off] [adaptive-tx on|off] [rx-usecs N] [rx-frames N] [rx-usecs-irq N]
	      [rx-frames-irq N] [tx-usecs N] [tx-frames N] [tx-usecs-irq N] [tx-frames-irq N] [stats-block-usecs N]
	      [pkt-rate-low N] [rx-usecs-low N] [rx-frames-low N] [tx-usecs-low N] [tx-frames-low N] [pkt-rate-high N]
	      [rx-usecs-high N] [rx-frames-high N] [tx-usecs-high N] [tx-frames-high N] [sample-interval N]
	      [cqe-mode-rx on|off] [cqe-mode-tx on|off] [tx-aggr-max-bytes N] [tx-aggr-max-frames N] [tx-aggr-time-usecs N]

       ethtool -g|--show-ring devname

       ethtool -G|--set-ring devname [rx N] [rx-mini N] [rx-jumbo N] [tx N] [rx-buf-len N] [tcp-data-split auto|on|off]
	      [hds-thresh N] [cqe-size N] [tx-push N] [rx-push N] [tx-push-buf-len N]

       ethtool -i|--driver devname

       ethtool -d|--register-dump devname [raw on|off] [hex on|off] [file name]

       ethtool -e|--eeprom-dump devname [raw on|off] [offset N] [length N]

       ethtool -E|--change-eeprom devname [magic N] [offset N] [length N] [value N]

       ethtool -k|--show-features|--show-offload devname

       ethtool -K|--features|--offload devname feature on|off ...

       ethtool -p|--identify devname [N]

       ethtool -P|--show-permaddr devname

       ethtool -r|--negotiate devname

       ethtool -S|--statistics devname [--all-groups|--groups [eth-phy] [eth-mac] [eth-ctrl] [rmon] ]

       ethtool --phy-statistics devname

       ethtool -t|--test devname [offline|online|external_lb]

       ethtool -s devname [speed N] [lanes N] [duplex half|full] [port tp|aui|bnc|mii] [mdix auto|on|off] [autoneg on|off]
	      [advertise N[/M] | advertise mode on|off ...]  [phyad N] [xcvr internal|external] [wol N[/M]
	      | wol p|u|m|b|a|g|s|f|d...]  [sopass xx:yy:zz:aa:bb:cc] [master-slave preferred-master|preferred-slave|forced-
	      master|forced-slave] [msglvl N[/M] | msglvl type on|off ...]

       ethtool -n|-u|--show-nfc|--show-ntuple devname [ rx-flow-hash tcp4|udp4|ah4|esp4|sctp4|tcp6|udp6|ah6|esp6|sctp6 |
	      rule N ]

       ethtool -N|-U|--config-nfc|--config-ntuple devname rx-flow-hash tcp4|udp4|ah4|esp4|sctp4|tcp6|udp6|ah6|esp6|sctp6
	      m|v|t|s|d|f|n|r... |
	      flow-type ether|ip4|tcp4|udp4|sctp4|ah4|esp4|ip6|tcp6|udp6|ah6|esp6|sctp6
	      [src xx:yy:zz:aa:bb:cc [m xx:yy:zz:aa:bb:cc]] [dst xx:yy:zz:aa:bb:cc [m xx:yy:zz:aa:bb:cc]] [proto N [m N]]
	      [src-ip ip-address [m ip-address]] [dst-ip ip-address [m ip-address]] [tos N [m N]] [tclass N [m N]]
	      [l4proto N [m N]] [src-port N [m N]] [dst-port N [m N]] [spi N [m N]] [l4data N [m N]] [vlan-etype N [m N]]
	      [vlan N [m N]] [user-def N [m N]] [dst-mac xx:yy:zz:aa:bb:cc [m xx:yy:zz:aa:bb:cc]] [action N] [context N]
	      [loc N] |
	      delete N

       ethtool -w|--get-dump devname [data filename]

       ethtool -W|--set-dump devname N

       ethtool -T|--show-time-stamping devname [index N qualifier precise|approx]

       ethtool --get-hwtimestamp-cfg devname

       ethtool --set-hwtimestamp-cfg devname [index N qualifier precise|approx] [tx TX-TYPE] [rx-filter RX-FILTER]

       ethtool -x|--show-rxfh-indir|--show-rxfh devname

       ethtool -X|--set-rxfh-indir|--rxfh devname [hkey xx:yy:zz:aa:bb:cc:...]	[start N] [ equal N | weight W0 W1
	      ... | default ] [hfunc FUNC] [xfrm symmetric-xor|symmetric-or-xor|none] [context CTX | new] [delete]

       ethtool -f|--flash devname file [N]

       ethtool -l|--show-channels devname

       ethtool -L|--set-channels devname [rx N] [tx N] [other N] [combined N]

       ethtool -m|--dump-module-eeprom|--module-info devname [raw on|off] [hex on|off] [offset N] [length N] [page N]
	      [bank N] [i2c N]

       ethtool --show-priv-flags devname

       ethtool --set-priv-flags devname flag on|off ...

       ethtool --show-eee devname

       ethtool --set-eee devname [eee on|off] [tx-lpi on|off] [tx-timer N] [advertise N]

       ethtool --set-phy-tunable devname [ downshift on|off [count N] ] [ fast-link-down on|off [msecs N] ] [
	      energy-detect-power-down on|off [msecs N] ]

       ethtool --get-phy-tunable devname [downshift] [fast-link-down] [energy-detect-power-down]

       ethtool --get-tunable devname [rx-copybreak] [tx-copybreak] [tx-buf-size] [pfc-prevention-tout]

       ethtool --set-tunable devname [rx-copybreak N] [tx-copybreak N] [tx-buf-size N] [pfc-prevention-tout N]

       ethtool --reset devname [flags N] [mgmt] [mgmt-shared] [irq] [irq-shared] [dma] [dma-shared] [filter] [filter-shared]
	      [offload] [offload-shared] [mac] [mac-shared] [phy] [phy-shared] [ram] [ram-shared] [ap] [ap-shared]
	      [dedicated] [all]

       ethtool --show-fec devname

       ethtool --set-fec devname encoding auto|off|rs|baser|llrs [...]

       ethtool -Q|--per-queue devname [queue_mask %x] sub_command ...

       ethtool --cable-test devname

       ethtool --cable-test-tdr devname [first N] [last N] [step N] [pair N]

       ethtool --show-tunnels devname

       ethtool --show-module devname

       ethtool --set-module devname [power-mode-policy high|auto]

       ethtool --get-plca-cfg devname

       ethtool --set-plca-cfg devname [enable on|off] [node-id N] [node-cnt N] [to-tmr N] [burst-cnt N] [burst-tmr N]

       ethtool --get-plca-status devname

       ethtool --show-mm devname

       ethtool --set-mm devname [verify-enabled on|off] [verify-time N] [tx-enabled on|off] [pmac-enabled on|off]
	      [tx-min-frag-size N]

       ethtool --show-pse devname

       ethtool --set-pse devname [podl-pse-admin-control enable|disable] [c33-pse-admin-control enable|disable]
	      [c33-pse-avail-pw-limit N] [prio N]

       ethtool --flash-module-firmware devname file FILE [pass PASS]

       ethtool --show-phys devname

DESCRIPTION
       ethtool is used to query and control network device driver and hardware settings, particularly for wired Ethernet de‐
       vices.

       devname is the name of the network device on which ethtool should operate.

OPTIONS
       ethtool with a single argument specifying the device name prints current settings of the specified device.

       -h --help
	      Shows a short help message.

       --version
	      Shows the ethtool version number.

       --debug N
	      Turns on debugging messages. Argument is interpreted as a mask:
	      0x01  Parser information
	      0x02  Summary of netlink messages
	      0x04  Hex dump of sent netlink messages
	      0x08  Hex dump of received netlink messages
	      0x10  Structure of netlink messages

       --disable-netlink
	      Do not use netlink and fall back to the ioctl interface if possible.

       --json Output results in JavaScript Object Notation (JSON). Only a subset of options support this. Those which do not
	      will continue to output plain text in the presence of this option.

       -I --include-statistics
	      Include command-related statistics in the output. This option allows displaying relevant device statistics for
	      selected get commands.

       --phy N
	      Target  a	 PHY  within the interface. The PHY index can be retrieved with --show-phys. PHY index 0 targets the
	      phy device directly attached to the ethernet MAC, if any.	 The following commands can accept a PHY index:
	      --cable-test
	      --cable-test-tdr
	      --get-plca-cfg
	      --set-plca-cfg
	      --get-plca-status
	      --show-pse
	      --set-pse

       -a --show-pause
	      Queries the specified Ethernet device for pause parameter information.

	   --src aggregate|emac|pmac
		  If the MAC Merge layer is supported, request a particular source of device statistics (eMAC  or  pMAC,  or
		  their aggregate). Only valid if ethtool was invoked with the -I --include-statistics argument.

       -A --pause
	      Changes the pause parameters of the specified Ethernet device.

	   autoneg on|off
		  Specifies whether pause autonegotiation should be enabled.

	   rx on|off
		  Specifies whether RX pause should be enabled.

	   tx on|off
		  Specifies whether TX pause should be enabled.

       -c --show-coalesce
	      Queries the specified network device for coalescing information.

       -C --coalesce
	      Changes the coalescing settings of the specified network device.

       -g --show-ring
	      Queries the specified network device for rx/tx ring parameter information.

       -G --set-ring
	      Changes the rx/tx ring parameters of the specified network device.

	   rx N	  Changes the number of ring entries for the Rx ring.

	   rx-mini N
		  Changes the number of ring entries for the Rx Mini ring.

	   rx-jumbo N
		  Changes the number of ring entries for the Rx Jumbo ring.

	   tx N	  Changes the number of ring entries for the Tx ring.

	   rx-buf-len N
		  Changes the size of a buffer in the Rx ring.

	   tcp-data-split auto|on|off
		  Specifies the state of TCP data split.

	   hds-thresh N
		  Specifies the threshold value of tcp data split

	   cqe-size N
		  Changes the size of completion queue event.

	   tx-push on|off
		  Specifies whether TX push should be enabled.

	   rx-push on|off
		  Specifies whether RX push should be enabled.

	   tx-push-buf-len N
		  Specifies the maximum number of bytes of a transmitted packet a driver can push directly to the underlying
		  device

       -i --driver
	      Queries the specified network device for associated driver information.

       -d --register-dump
	      Retrieves	 and  prints a register dump for the specified network device.	The register format for some devices
	      is known and decoded others are printed in hex.  When raw is enabled, then ethtool dumps the raw register data
	      to stdout.  If file is specified, then use contents of previous raw register dump, rather	 than  reading	from
	      the device.

       -e --eeprom-dump
	      Retrieves	 and prints an EEPROM dump for the specified network device.  When raw is enabled, then it dumps the
	      raw EEPROM data to stdout. The length and offset parameters allow dumping certain portions of the EEPROM.	 De‐
	      fault is to dump the entire EEPROM.

	   raw on|off

	   offset N

	   length N

       -E --change-eeprom
	      If value is specified, changes EEPROM byte for the specified network device.  offset and value  specify  which
	      byte  and	 it's  new value. If value is not specified, stdin is read and written to the EEPROM. The length and
	      offset parameters allow writing to certain portions of the EEPROM.  Because of the persistent nature of  writ‐
	      ing to the EEPROM, a device-specific magic key must be specified to prevent the accidental writing to the EEP‐
	      ROM.

       -k --show-features --show-offload
	      Queries the specified network device for the state of protocol offload and other features.

       -K --features --offload
	      Changes  the  offload  parameters	 and  other features of the specified network device.  The following feature
	      names are built-in and others may be defined by the kernel.

	   rx on|off
		  Specifies whether RX checksumming should be enabled.

	   tx on|off
		  Specifies whether TX checksumming should be enabled.

	   sg on|off
		  Specifies whether scatter-gather should be enabled.

	   tso on|off
		  Specifies whether TCP segmentation offload should be enabled.

	   ufo on|off
		  Specifies whether UDP fragmentation offload should be enabled

	   gso on|off
		  Specifies whether generic segmentation offload should be enabled

	   gro on|off
		  Specifies whether generic receive offload should be enabled

	   lro on|off
		  Specifies whether large receive offload should be enabled

	   rxvlan on|off
		  Specifies whether RX VLAN acceleration should be enabled

	   txvlan on|off
		  Specifies whether TX VLAN acceleration should be enabled

	   ntuple on|off
		  Specifies whether Rx ntuple filters and actions should be enabled

	   rxhash on|off
		  Specifies whether receive hashing offload should be enabled

       -p --identify
	      Initiates adapter-specific action intended to enable an operator to easily  identify  the	 adapter  by  sight.
	      Typically this involves blinking one or more LEDs on the specific network port.

	   [ N]	  Length of time to perform phys-id, in seconds.

       -P --show-permaddr
	      Queries the specified network device for permanent hardware address.

       -r --negotiate
	      Restarts auto-negotiation on the specified Ethernet device, if auto-negotiation is enabled.

       -S --statistics
	      Queries  the specified network device for standard (IEEE, IETF, etc.), or NIC- and driver-specific statistics.
	      NIC- and driver-specific statistics are requested when no group of statistics is specified.

	      NIC- and driver-specific statistics and standard statistics are independent,  devices  may  implement  either,
	      both  or	none.  There is little commonality between naming of NIC- and driver-specific statistics across ven‐
	      dors.

	   --all-groups

	   --groups [eth-phy] [eth-mac] [eth-ctrl] [rmon]
		  Request groups of standard device statistics.

	   --src aggregate|emac|pmac
		  If the MAC Merge layer is supported, request a particular source of device statistics (eMAC  or  pMAC,  or
		  their aggregate).

       --phy-statistics
	      Queries the specified network device for PHY specific statistics.

       -t --test
	      Executes adapter selftest on the specified network device. Possible test modes are:

	   offline
		  Perform full set of tests, possibly interrupting normal operation during the tests,

	   online Perform limited set of tests, not interrupting normal operation,

	   external_lb
		  Perform full set of tests, as for offline, and additionally an external-loopback test.

       -s --change
	      Allows  changing some or all settings of the specified network device.  All following options only apply if -s
	      was specified.

	   speed N
		  Set speed in Mb/s.  ethtool with just the device name as an argument will show you  the  supported  device
		  speeds.

	   lanes N
		  Set number of lanes.

	   duplex half|full
		  Sets full or half duplex mode.

	   port tp|aui|bnc|mii
		  Selects device port.

	   master-slave preferred-master|preferred-slave|forced-master|forced-slave
		  Configure  MASTER/SLAVE  role	 of the PHY. When the PHY is configured as MASTER, the PMA Transmit function
		  shall source TX_TCLK from a local clock source. When configured as SLAVE, the PMA Transmit function  shall
		  source TX_TCLK from the clock recovered from data stream provided by MASTER. Not all devices support this.
		  preferred-master   Prefer MASTER role on autonegotiation
		  preferred-slave    Prefer SLAVE role on autonegotiation
		  forced-master	     Force the PHY in MASTER role. Can be used without autonegotiation
		  forced-slave	     Force the PHY in SLAVE role. Can be used without autonegotiation

	   mdix auto|on|off
		  Selects  MDI-X mode for port. May be used to override the automatic detection feature of most adapters. An
		  argument of auto means automatic detection of MDI status, on forces  MDI-X  (crossover)  mode,  while	 off
		  means	 MDI (straight through) mode.  The driver should guarantee that this command takes effect immediate‐
		  ly, and if necessary may reset the link to cause the change to take effect.

	   autoneg on|off
		  Specifies whether autonegotiation should be enabled. Autonegotiation is enabled by default,  but  in	some
		  network devices may have trouble with it, so you can disable it if really necessary.

	   advertise N
		  Sets the speed and duplex advertised by autonegotiation.  The argument is a hexadecimal value using one or
		  a combination of the following values:
		  0x001				      10baseT Half
		  0x002				      10baseT Full
		  0x100000000000000000000000	      10baseT1L Full
		  0x8000000000000000000000000	      10baseT1S Full
		  0x10000000000000000000000000	      10baseT1S Half
		  0x20000000000000000000000000	      10baseT1S_P2MP Half
		  0x40000000000000000000000000	      10baseT1BRR Full
		  0x004				      100baseT Half
		  0x008				      100baseT Full
		  0x80000000000000000		      100baseT1 Full
		  0x40000000000000000000000	      100baseFX Half
		  0x80000000000000000000000	      100baseFX Full
		  0x010				      1000baseT Half		   (not supported by IEEE standards)
		  0x020				      1000baseT Full
		  0x20000			      1000baseKX Full
		  0x20000000000			      1000baseX Full
		  0x100000000000000000		      1000baseT1 Full
		  0x8000			      2500baseX Full		   (not supported by IEEE standards)
		  0x800000000000		      2500baseT Full
		  0x1000000000000		      5000baseT Full
		  0x1000			      10000baseT Full
		  0x40000			      10000baseKX4 Full
		  0x80000			      10000baseKR Full
		  0x100000			      10000baseR_FEC
		  0x40000000000			      10000baseCR Full
		  0x80000000000			      10000baseSR Full
		  0x100000000000		      10000baseLR Full
		  0x200000000000		      10000baseLRM Full
		  0x400000000000		      10000baseER Full
		  0x200000			      20000baseMLD2 Full	   (not supported by IEEE standards)
		  0x400000			      20000baseKR2 Full		   (not supported by IEEE standards)
		  0x80000000			      25000baseCR Full
		  0x100000000			      25000baseKR Full
		  0x200000000			      25000baseSR Full
		  0x800000			      40000baseKR4 Full
		  0x1000000			      40000baseCR4 Full
		  0x2000000			      40000baseSR4 Full
		  0x4000000			      40000baseLR4 Full
		  0x400000000			      50000baseCR2 Full
		  0x800000000			      50000baseKR2 Full
		  0x10000000000			      50000baseSR2 Full
		  0x10000000000000		      50000baseKR Full
		  0x20000000000000		      50000baseSR Full
		  0x40000000000000		      50000baseCR Full
		  0x80000000000000		      50000baseLR_ER_FR Full
		  0x100000000000000		      50000baseDR Full
		  0x8000000			      56000baseKR4 Full
		  0x10000000			      56000baseCR4 Full
		  0x20000000			      56000baseSR4 Full
		  0x40000000			      56000baseLR4 Full
		  0x1000000000			      100000baseKR4 Full
		  0x2000000000			      100000baseSR4 Full
		  0x4000000000			      100000baseCR4 Full
		  0x8000000000			      100000baseLR4_ER4 Full
		  0x200000000000000		      100000baseKR2 Full
		  0x400000000000000		      100000baseSR2 Full
		  0x800000000000000		      100000baseCR2 Full
		  0x1000000000000000		      100000baseLR2_ER2_FR2 Full
		  0x2000000000000000		      100000baseDR2 Full
		  0x8000000000000000000		      100000baseKR Full
		  0x10000000000000000000	      100000baseSR Full
		  0x20000000000000000000	      100000baseLR_ER_FR Full
		  0x40000000000000000000	      100000baseCR Full
		  0x80000000000000000000	      100000baseDR Full
		  0x4000000000000000		      200000baseKR4 Full
		  0x8000000000000000		      200000baseSR4 Full
		  0x10000000000000000		      200000baseLR4_ER4_FR4 Full
		  0x20000000000000000		      200000baseDR4 Full
		  0x40000000000000000		      200000baseCR4 Full
		  0x100000000000000000000	      200000baseKR2 Full
		  0x200000000000000000000	      200000baseSR2 Full
		  0x400000000000000000000	      200000baseLR2_ER2_FR2 Full
		  0x800000000000000000000	      200000baseDR2 Full
		  0x1000000000000000000000	      200000baseCR2 Full
		  0x80000000000000000000000000	      200000baseCR Full
		  0x100000000000000000000000000	      200000baseKR Full
		  0x200000000000000000000000000	      200000baseDR Full
		  0x400000000000000000000000000	      200000baseDR_2 Full
		  0x800000000000000000000000000	      200000baseSR Full
		  0x1000000000000000000000000000      200000baseVR Full
		  0x200000000000000000		      400000baseKR8 Full
		  0x400000000000000000		      400000baseSR8 Full
		  0x800000000000000000		      400000baseLR8_ER8_FR8 Full
		  0x1000000000000000000		      400000baseDR8 Full
		  0x2000000000000000000		      400000baseCR8 Full
		  0x2000000000000000000000	      400000baseKR4 Full
		  0x4000000000000000000000	      400000baseSR4 Full
		  0x8000000000000000000000	      400000baseLR4_ER4_FR4 Full
		  0x10000000000000000000000	      400000baseDR4 Full
		  0x20000000000000000000000	      400000baseCR4 Full
		  0x2000000000000000000000000000      400000baseCR2 Full
		  0x4000000000000000000000000000      400000baseKR2 Full
		  0x8000000000000000000000000000      400000baseDR2 Full
		  0x10000000000000000000000000000     400000baseDR2_2 Full
		  0x20000000000000000000000000000     400000baseSR2 Full
		  0x40000000000000000000000000000     400000baseVR2 Full
		  0x200000000000000000000000	      800000baseCR8 Full
		  0x400000000000000000000000	      800000baseKR8 Full
		  0x800000000000000000000000	      800000baseDR8 Full
		  0x1000000000000000000000000	      800000baseDR8_2 Full
		  0x2000000000000000000000000	      800000baseSR8 Full
		  0x4000000000000000000000000	      800000baseVR8 Full
		  0x80000000000000000000000000000     800000baseCR4 Full
		  0x100000000000000000000000000000    800000baseKR4 Full
		  0x200000000000000000000000000000    800000baseDR4 Full
		  0x400000000000000000000000000000    800000baseDR4_2 Full
		  0x800000000000000000000000000000    800000baseSR4 Full
		  0x1000000000000000000000000000000   800000baseVR4 Full

	   phyad N
		  PHY address.

	   xcvr internal|external
		  Selects  transceiver	type.  Currently  only internal and external can be specified, in the future further
		  types might be added.

	   wol p|u|m|b|a|g|s|f|d...
		  Sets Wake-on-LAN options.  Not all devices support this.  The argument to this option is a string of char‐
		  acters specifying which options to enable.
		  p   Wake on PHY activity
		  u   Wake on unicast messages
		  m   Wake on multicast messages
		  b   Wake on broadcast messages
		  a   Wake on ARP
		  g   Wake on MagicPacketā„¢
		  s   Enable SecureOnā„¢ password for MagicPacketā„¢
		  f   Wake on filter(s)
		  d   Disable (wake on	nothing).   This  option
		      clears all previous options.

	   sopass xx:yy:zz:aa:bb:cc
		  Sets	the  SecureOnā„¢	password.   The	 argument  to this option must be 6 bytes in Ethernet MAC hex format
		  (xx:yy:zz:aa:bb:cc).

	   msglvl N
	   msglvl type on|off ...
		  Sets the driver message type flags by name or number. type names the type of message to enable or disable;
		  N specifies the new flags numerically. The defined type names and numbers are:
		  drv	      0x0001  General driver status
		  probe	      0x0002  Hardware probing
		  link	      0x0004  Link state
		  timer	      0x0008  Periodic status check
		  ifdown      0x0010  Interface being brought down
		  ifup	      0x0020  Interface being brought up
		  rx_err      0x0040  Receive error
		  tx_err      0x0080  Transmit error
		  tx_queued   0x0100  Transmit queueing
		  intr	      0x0200  Interrupt handling
		  tx_done     0x0400  Transmit completion
		  rx_status   0x0800  Receive completion
		  pktdata     0x1000  Packet contents
		  hw	      0x2000  Hardware status
		  wol	      0x4000  Wake-on-LAN status

		  The precise meanings of these type flags differ between drivers.

       -n -u --show-nfc --show-ntuple
	      Retrieves receive network flow classification options or rules.

	   rx-flow-hash tcp4|udp4|ah4|esp4|sctp4|tcp6|udp6|ah6|esp6|sctp6
		  Retrieves the hash options for the specified flow type.
		  tcp4	  TCP over IPv4
		  udp4	  UDP over IPv4
		  ah4	  IPSEC AH over IPv4
		  esp4	  IPSEC ESP over IPv4
		  sctp4	  SCTP over IPv4
		  tcp6	  TCP over IPv6
		  udp6	  UDP over IPv6
		  ah6	  IPSEC AH over IPv6
		  esp6	  IPSEC ESP over IPv6
		  sctp6	  SCTP over IPv6

	   rule N Retrieves the RX classification rule with the given ID.

       -N -U --config-nfc --config-ntuple
	      Configures receive network flow classification options or rules.

	   rx-flow-hash tcp4|udp4|ah4|esp4|sctp4|tcp6|udp6|ah6|esp6|sctp6m|v|t|s|d|f|n|r...
		  Configures the hash options for the specified flow type.
		  m   Hash on the Layer 2 destination address of the rx packet.
		  v   Hash on the VLAN tag of the rx packet.
		  t   Hash on the Layer 3 protocol field of the rx packet.
		  s   Hash on the IP source address of the rx packet.
		  d   Hash on the IP destination address of the rx packet.
		  f   Hash on bytes 0 and 1 of the Layer 4 header of the rx packet.
		  n   Hash on bytes 2 and 3 of the Layer 4 header of the rx packet.
		  l   Hash on IPv6 Flow Label of the rx packet.
		  r   Discard all packets of this flow type. When  this	 option	 is
		      set, all other options are ignored.

	   flow-type ether|ip4|tcp4|udp4|sctp4|ah4|esp4|ip6|tcp6|udp6|ah6|esp6|sctp6
		  Inserts or updates a classification rule for the specified flow type.
		  ether	  Ethernet
		  ip4	  Raw IPv4
		  tcp4	  TCP over IPv4
		  udp4	  UDP over IPv4
		  sctp4	  SCTP over IPv4
		  ah4	  IPSEC AH over IPv4
		  esp4	  IPSEC ESP over IPv4
		  ip6	  Raw IPv6
		  tcp6	  TCP over IPv6
		  udp6	  UDP over IPv6
		  sctp6	  SCTP over IPv6
		  ah6	  IPSEC AH over IPv6
		  esp6	  IPSEC ESP over IPv6

	   For	all  fields  that allow both a value and a mask to be specified, the mask may be specified immediately after
	   the value using the m keyword, or separately using the field name keyword with -mask appended, e.g. src-mask.

	   src xx:yy:zz:aa:bb:cc [m xx:yy:zz:aa:bb:cc]
		  Includes the source MAC address, specified as 6 bytes in hexadecimal separated by colons,  along  with  an
		  optional mask.  Valid only for flow-type ether.

	   dst xx:yy:zz:aa:bb:cc [m xx:yy:zz:aa:bb:cc]
		  Includes  the destination MAC address, specified as 6 bytes in hexadecimal separated by colons, along with
		  an optional mask.  Valid only for flow-type ether.

	   proto N [m N]
		  Includes the Ethernet protocol number (ethertype) and an optional mask.  Valid only for flow-type ether.

	   src-ip ip-address [m ip-address]
		  Specify the source IP address of the incoming packet to match along with an optional mask.  Valid for	 all
		  IP based flow-types.

	   dst-ip ip-address [m ip-address]
		  Specify the destination IP address of the incoming packet to match along with an optional mask.  Valid for
		  all IP based flow-types.

	   tos N [m N]
		  Specify  the	value  of  the	Type of Service field in the incoming packet to match along with an optional
		  mask.	 Applies to all IPv4 based flow-types.

	   tclass N [m N]
		  Specify the value of the Traffic Class field in the incoming packet to match along with an optional  mask.
		  Applies to all IPv6 based flow-types.

	   l4proto N [m N]
		  Includes the layer 4 protocol number and optional mask.  Valid only for flow-types ip4 and ip6.

	   src-port N [m N]
		  Specify the value of the source port field (applicable to TCP/UDP packets) in the incoming packet to match
		  along with an optional mask.	Valid for flow-types ip4, tcp4, udp4, and sctp4 and their IPv6 equivalents.

	   dst-port N [m N]
		  Specify  the	value of the destination port field (applicable to TCP/UDP packets)in the incoming packet to
		  match along with an optional mask.  Valid for flow-types ip4, tcp4, udp4, and sctp4 and their IPv6 equiva‐
		  lents.

	   spi N [m N]
		  Specify the value of the security parameter index field (applicable  to  AH/ESP  packets)in  the  incoming
		  packet  to  match  along  with  an  optional mask.  Valid for flow-types ip4, ah4, and esp4 and their IPv6
		  equivalents.

	   l4data N [m N]
		  Specify the value of the first 4 Bytes of Layer 4 in the incoming packet to match along with	an  optional
		  mask.	 Valid for ip4 and ip6 flow-types.

	   vlan-etype N [m N]
		  Includes the VLAN tag Ethertype and an optional mask.

	   vlan N [m N]
		  Includes the VLAN tag and an optional mask.

	   user-def N [m N]
		  Includes 64-bits of user-specific data and an optional mask.

	   dst-mac xx:yy:zz:aa:bb:cc [m xx:yy:zz:aa:bb:cc]
		  Includes  the destination MAC address, specified as 6 bytes in hexadecimal separated by colons, along with
		  an optional mask.  Valid for all IP based flow-types.

	   action N
		  Specifies the Rx queue to send packets to, or some other action.
		  -1		Drop the matched flow
		  -2		Use the matched flow as a Wake-on-LAN filter
		  0 or higher	Rx queue to route the flow

	   context N
		  Specifies the RSS context to spread packets over multiple queues; either 0 for the default RSS context, or
		  a value returned by ethtool -X ... context new.  If combined with action or queue, the Rx queue  specified
		  will	be  added to the value read from the RSS indirection table to produce the actual Rx queue to deliver
		  to.

	   vf N	  Specifies the Virtual Function the filter applies to. Not compatible with action.

	   queue N
		  Specifies the Rx queue to send packets to. Not compatible with action.

	   loc N  Specify the location/ID to insert the rule. This will overwrite any rule present in that location and will
		  not go through any of the rule ordering process.

	   delete N
		  Deletes the RX classification rule with the given ID.

       -w --get-dump
	      Retrieves and prints firmware dump for the specified network device.  By default, it prints out the dump flag,
	      version and length of the dump data.  When data is indicated, then ethtool fetches the dump data	and  directs
	      it to a file.

       -W --set-dump
	      Sets the dump flag for the device.

       -T --show-time-stamping
	      Show  the	 device's time stamping capabilities and associated PTP hardware clock. Show the capabilities of the
	      currently selected time stamping if no index and qualifier is provided.

	   index N
		  Index of the ptp hardware clock

	   qualifier precise|approx
		  Qualifier of the ptp hardware clock. Mainly "precise" the default one is for IEEE 1588  quality  and	"ap‐
		  prox" is for NICs DMA point.

       --get-hwtimestamp-cfg
	      Show the selected time stamping PTP hardware clock configuration.

       --set-hwtimestamp-cfg
	      Sets the device's time stamping PTP hardware clock configuration.

	   index N
		  Index of the ptp hardware clock

	   qualifier precise|approx
		  Qualifier  of	 the  ptp hardware clock. Mainly "precise" the default one is for IEEE 1588 quality and "ap‐
		  prox" is for NICs DMA point.

	   tx TX-TYPE
		  Type of TX time stamping to configure

	   rx-filter RX-FILTER
		  Type of RX time stamping filter to configure

       -x --show-rxfh-indir --show-rxfh
	      Retrieves the receive flow hash indirection table and/or RSS hash key.

       -X --set-rxfh-indir --rxfh
	      Configures the receive flow hash indirection table and/or RSS hash key.

	   hkey	  Sets RSS hash key of the specified network device. RSS hash key should  be  of  device  supported  length.
		  Hash key format must be in xx:yy:zz:aa:bb:cc format meaning both the nibbles of a byte should be mentioned
		  even if a nibble is zero.

	   hfunc  Sets	RSS hash function of the specified network device.  List of RSS hash functions which kernel supports
		  is shown as a part of the --show-rxfh command output.

	   xfrm	  Sets the RSS input transformation. Currently, only the symmetric-xor and symmetric-or-xor  transformations
		  are supported where the NIC XORs/ORs the L3 and/or L4 source and destination fields (as selected by --con‐
		  fig-nfc  rx-flow-hash	 )  before passing them to the hash algorithm. The RSS hash function will then yield
		  the same hash for the other flow direction where the source and destination fields are swapped (i.e.	Sym‐
		  metric  RSS).	 Note  that this operation reduces the entropy of the input set and the hash algorithm could
		  potentially be exploited. Switch off by xfrm none.

	   start N
		  For the equal and weight options, sets the starting receive queue for spreading flows to N.

	   equal N
		  Sets the receive flow hash indirection table to spread flows evenly between the first N receive queues.

	   weight W0 W1 ...
		  Sets the receive flow hash indirection table to spread flows between receive queues according to the given
		  weights.  The sum of the weights must be non-zero and must not exceed the size of the indirection table.

	   default
		  Sets the receive flow hash indirection table to its default value.

	   context CTX | new
		  Specifies an RSS context to act on; either new to allocate a new RSS context, or CTX, a value returned  by
		  a previous ... context new.

	   delete Delete the specified RSS context.  May only be used in conjunction with context and a non-zero CTX value.

       -f --flash
	      Write a firmware image to flash or other non-volatile memory on the device.

	   file	  Specifies the filename of the firmware image.	 The firmware must first be installed in one of the directo‐
		  ries where the kernel firmware loader or firmware agent will look, such as /lib/firmware.

	   N	  If  the  device stores multiple firmware images in separate regions of non-volatile memory, this parameter
		  may be used to specify which region is to be written.	 The default is 0, requesting that all	regions	 are
		  written.  All other values are driver-dependent.

       -l --show-channels
	      Queries  the  specified network device for the numbers of channels it has.  A channel is an IRQ and the set of
	      queues that can trigger that IRQ.

       -L --set-channels
	      Changes the numbers of channels of the specified network device.

	   rx N	  Changes the number of channels with only receive queues.

	   tx N	  Changes the number of channels with only transmit queues.

	   other N
		  Changes the number of channels used only for other purposes e.g. link interrupts or SR-IOV co-ordination.

	   combined N
		  Changes the number of multi-purpose channels.

       -m --dump-module-eeprom --module-info
	      Retrieves and if possible decodes the EEPROM from plugin modules, e.g SFP+, QSFP.	 If the	 driver	 and  module
	      support it, the optical diagnostic information is also read and decoded.	When either one of page, bank or i2c
	      parameters  is  specified,  dumps	 only  of a single page or its portion is allowed. In such a case offset and
	      length parameters are treated relatively to EEPROM page boundaries.

       --show-priv-flags
	      Queries the specified network device for its private flags.  The names and meanings of private flags (if	any)
	      are defined by each network device driver.

       --set-priv-flags
	      Sets the device's private flags as specified.

	   flag on|off Sets the state of the named private flag.

       --show-eee
	      Queries  the  specified  network	device	for  its support of Energy-Efficient Ethernet (according to the IEEE
	      802.3az specifications)

       --set-eee
	      Sets the device EEE behaviour.

	   eee on|off
		  Enables/disables the device support of EEE.

	   tx-lpi on|off
		  Determines whether the device should assert its Tx LPI.

	   advertise N
		  Sets the speeds for which the device should advertise EEE capabilities.  Values are as for --change adver‐
		  tise

	   tx-timer N
		  Sets the amount of time the device should stay in idle mode prior to asserting its Tx	 LPI  (in  microsec‐
		  onds). This has meaning only when Tx LPI is enabled.

       --set-phy-tunable
	      Sets the PHY tunable parameters.

	   downshift on|off
		  Specifies whether downshift should be enabled.
		  count N
		      Sets the PHY downshift re-tries count.

	   fast-link-down on|off
		  Specifies whether Fast Link Down should be enabled and time until link down (if supported).
		  msecs N
		      Sets the period after which the link is reported as down. Note that the PHY may choose
		      the closest supported value. Only on reading back the tunable do you get the actual value.

	   energy-detect-power-down on|off
		  Specifies  whether Energy Detect Power Down (EDPD) should be enabled (if supported).	This will put the RX
		  and TX circuit blocks into a low power mode, and the PHY will wake up periodically to send link pulses  to
		  avoid any lock-up situation with a peer PHY that may also have EDPD enabled. By default, this setting will
		  also enable the periodic transmission of TX pulses.
		  msecs N
		      Some PHYs support configuration of the wake-up interval to send TX pulses.
		      This setting allows the control of this interval, and 0 disables TX pulses
		      if the PHY supports this. Disabling TX pulses can create a lock-up situation
		      where neither of the PHYs wakes the other one. If unspecified the default
		      value (in milliseconds) will be used by the PHY.

       --get-phy-tunable
	      Gets the PHY tunable parameters.

	   downshift
		  For  operation in cabling environments that are incompatible with 1000BASE-T, PHY device provides an auto‐
		  matic link speed downshift operation.	 Link speed downshift after N failed 1000BASE-T auto-negotiation at‐
		  tempts.  Downshift is useful where cable does not have the 4 pairs instance.

		  Gets the PHY downshift count/status.

	   fast-link-down
		  Depending on the mode it may take 0.5s - 1s until a broken link is reported as down.	In certain use cases
		  a link-down event needs to be reported as soon as possible.  Some PHYs support a Fast	 Link  Down  Feature
		  and may allow configuration of the delay before a broken link is reported as being down.

		  Gets the PHY Fast Link Down status / period.

	   energy-detect-power-down
		  Gets the current configured setting for Energy Detect Power Down (if supported).

       --get-tunable
	      Get the tunable parameters.

	   rx-copybreak
		  Get the current rx copybreak value in bytes.

	   tx-copybreak
		  Get the current tx copybreak value in bytes.

	   tx-buf-size
		  Get the current tx copybreak buffer size in bytes.

	   pfc-prevention-tout
		  Get the current pfc prevention timeout value in msecs.

       --set-tunable
	      Set driver's tunable parameters.

	   rx-copybreak N
		  Set the rx copybreak value in bytes.

	   tx-copybreak N
		  Set the tx copybreak value in bytes.

	   tx-buf-size N
		  Set the tx copybreak buffer size in bytes.

	   pfc-prevention-tout N
		  Set pfc prevention timeout in msecs. Value of 0 means disable and 65535 means auto.

       --reset
	      Reset hardware components specified by flags and components listed below

	   flags N
		  Resets the components based on direct flags mask

	   mgmt	  Management processor

	   irq	  Interrupt requester

	   dma	  DMA engine

	   filter Filtering/flow direction

	   offload
		  Protocol offload

	   mac	  Media access controller

	   phy	  Transceiver/PHY

	   ram	  RAM shared between multiple components ap Application Processor

	   dedicated
		  All components dedicated to this interface

	   all	  All components used by this interface, even if shared

       --show-fec
	      Queries the specified network device for its support of Forward Error Correction.

       --set-fec
	      Configures Forward Error Correction for the specified network device.

	      Forward  Error Correction modes selected by a user are expected to be persisted after any hotplug events. If a
	      module is swapped that does not support the current FEC mode, the driver or firmware must take the  link	down
	      administratively and report the problem in the system logs for users to correct.

	   encoding auto|off|rs|baser|llrs [...]

		  Sets	the  FEC encoding for the device.  Combinations of options are specified as e.g.  encoding auto rs ;
		  the semantics of such combinations vary between drivers.
		  auto	  Use the driver's default encoding
		  off	  Turn off FEC
		  RS	  Force RS-FEC encoding
		  BaseR	  Force BaseR encoding
		  LLRS	  Force LLRS-FEC encoding

       -Q|--per-queue
	      Applies provided sub command to specific queues.

	   queue_mask %x
		  Sets the specific queues which the sub command is applied to.	 If queue_mask is not set, the	sub  command
		  will be applied to all queues.

	   sub_command
		  Sub command to apply. The supported sub commands include --show-coalesce and --coalesce.

       --cable-test
	      Perform a cable test and report the results. What results are returned depends on the capabilities of the net‐
	      work  interface.	Typically  open	 pairs and shorted pairs can be reported, along with pairs being O.K. When a
	      fault is detected the approximate distance to the fault may be reported.

       --cable-test-tdr
	      Perform a cable test and report the raw Time Domain Reflectometer data.  A pulse is sent down a cable pair and
	      the amplitude of the reflection, for a given distance, is reported. A break in the cable returns a big reflec‐
	      tion. Minor damage to the cable returns a small reflection. If the cable is shorted, the amplitude of the	 re‐
	      flection	can  be	 negative.  By default, data is returned for lengths between 0 and 150m at 1m steps, for all
	      pairs. However parameters can be passed to restrict the collection of data. It should be noted, that  the	 in‐
	      terface  will  round the distances to whatever granularity is actually implemented. This is often 0.8 of a me‐
	      ter. The results should include the actual rounded first and last distance and step size.

	   first  N
		  Distance along the cable, in meters, where the first measurement should be made.

	   last	 N
		  Distance along the cable, in meters, where the last measurement should be made.

	   step	 N
		  Distance, in meters, between each measurement.

	   pair	 N
		  Which pair should be measured. Typically a cable has 4 pairs. 0 = Pair A, 1 = Pair B, ...

       --monitor
	      Listens to netlink notification and displays them.

	   command
		  If argument matching a command is used, ethtool only shows notifications of this type. Without such  argu‐
		  ment or with --all, all notification types are shown.

	   devname
		  If  a device name is used as argument, only notification for this device are shown. Default is to show no‐
		  tifications for all devices.

       --show-tunnels
	      Show tunnel-related device capabilities and state.  List UDP ports kernel has programmed the device  to  parse
	      as VxLAN, or GENEVE tunnels.

       --show-module
	      Show the transceiver module's parameters.

       --set-module
	      Set the transceiver module's parameters.

	   power-mode-policy high|auto
		  Set the power mode policy for the module. When set to high, the module always operates at high power mode.
		  When	set  to auto, the module is transitioned by the host to high power mode when the first port using it
		  is put administratively up and to low power mode when the last port using it is put administratively down.
		  The power mode policy can be set before a module is plugged-in.

       --get-plca-cfg
	      Show the current PLCA parameters for the given interface.

       --set-plca-cfg
	      Change the PLCA settings for the given interface.

	   enable on|off
		  Enables or disables the PLCA function. When the PLCA RS is disabled (default), the PHY operates  in  plain
		  CSMA/CD  mode.  To  enable PLCA, the PHY must be assigned a unique plca-id other than 255. This one can be
		  configured concurrently with the enable parameter. The enable parameter maps to IEEE	802.3cg-2019  clause
		  30.16.1.1.1 (aPLCAAdminState) and clause 30.16.1.2.1 (acPLCAAdminControl).

	   node-id N
		  The  unique  node  identifier in the range [0 .. 255]. Node ID 0 is reserved for the coordinator node, the
		  one generating the BEACON signal. There must be exactly one coordinator on a	PLCA  network.	Setting	 the
		  node	ID  to	255 (default) disables the node. This parameter maps to IEEE 802.3cg-2019 clause 30.16.1.1.4
		  (aPLCALocalNodeID).

	   node-cnt N
		  The node-cnt [1 .. 255] should be set after the maximum number of nodes that can be plugged to the  multi-
		  drop	network.  This parameter regulates the minimum length of the PLCA cycle. Therefore, it is only mean‐
		  ingful for the coordinator node (nod-id = 0). Setting this parameter on a follower node has no effect. The
		  node-cnt parameter maps to IEEE 802.3cg-2019 clause 30.16.1.1.3 (aPLCANodeCount).

	   to-tmr N
		  The TO timer parameter sets the value of the transmit opportunity timer in bit-times,	 and  shall  be	 set
		  equal	 across all the nodes sharing the same medium for PLCA to work. The default value of 32 is enough to
		  cover a link of roughly 50 mt. This parameter maps to	 IEEE 802.3cg-2019 clause 30.16.1.1.5 (aPLCATransmi‐
		  tOpportunityTimer).

	   burst-cnt N
		  The burst-cnt parameter [0 .. 255] indicates the extra number of packets that the node is allowed to	send
		  during  a  single transmit opportunity.  By default, this attribute is 0, meaning that the node can send a
		  sigle frame per TO. When greater than 0, the PLCA RS keeps the TO after any transmission, waiting for	 the
		  MAC  to send a new frame for up to burst-tmr BTs. This can only happen a number of times per PLCA cycle up
		  to the value of this parameter.  After that, the burst is over and the normal	 counting  of  TOs  resumes.
		  This parameter maps to IEEE 802.3cg-2019 clause 30.16.1.1.6 (aPLCAMaxBurstCount).

	   burst-tmr N
		  The burst-tmr parameter [0 .. 255] sets how many bit-times the PLCA RS waits for the MAC to initiate a new
		  transmission	when burst-cnt is greater than 0. If the MAC fails to send a new frame within this time, the
		  burst ends and the counting of TOs resumes. Otherwise, the new frame is sent as part of the current burst.
		  This parameter maps to IEEE 802.3cg-2019 clause 30.16.1.1.7  (aPLCABurstTimer).  The	value  of  burst-tmr
		  should  be  set  greater  than the Inter-Frame-Gap (IFG) time of the MAC (plus some margin) for PLCA burst
		  mode to work as intended.

       --get-plca-status
	      Show the current PLCA status for the given interface. If on, the PHY is successfully receiving  or  generating
	      the BEACON signal. If off, the PLCA function is temporarily disabled and the PHY is operating in plain CSMA/CD
	      mode.

       --show-mm
	      Show  the	 MAC  Merge layer state. The ethtool argument -I --include-statistics can be used with this command,
	      and MAC Merge layer statistics counters will also be retrieved.

	   pmac-enabled
		  Shows whether the pMAC is enabled and capable of receiving traffic and SMD-V	frames	(and  responding  to
		  them with SMD-R replies).

	   tx-enabled
		  Shows whether transmission on the pMAC is administratively enabled.

	   tx-active
		  Shows whether transmission on the pMAC is active (verification is either successful, or was disabled).

	   tx-min-frag-size
		  Shows	 the  minimum  size (in octets) of transmitted non-final fragments which can be received by the link
		  partner. Corresponds to the standard addFragSize variable using the formula:

		  tx-min-frag-size = 64 * (1 + addFragSize) - 4

	   rx-min-frag-size
		  Shows the minimum size (in octets) of non-final fragments which the local device supports receiving.

	   verify-enabled
		  Shows whether the verification state machine is enabled. This process, if successful,	 ensures  that	pre‐
		  emptible frames transmitted by the local device will not be dropped as error frames by the link partner.

	   verify-time
		  Shows	 the  interval	in ms between verification attempts, represented as an integer between 1 and 128 ms.
		  The standard defines a fixed number of verification attempts (verifyLimit) before failing the verification
		  process.

	   max-verify-time
		  Shows the maximum value for verify-time accepted by the local device, which may be less than 128 ms.

	   verify-status
		  Shows the current state of the verification state machine of the local device.   Values  can	be  INITIAL,
		  VERIFYING, SUCCEEDED, FAILED or DISABLED.

       --set-mm
	      Set the MAC Merge layer parameters.

	   pmac-enabled	 on|off
		  Enable reception for the pMAC.

	   tx-enabled  on|off
		  Administatively enable transmission for the pMAC.

	   tx-min-frag-size  N
		  Set  the  minimum  size  (in	octets) of transmitted non-final fragments which can be received by the link
		  partner.

	   verify-enabled  on|off
		  Enable or disable the verification state machine.

	   verify-time	N
		  Set the interval in ms between verification attempts.

       --show-pse
	      Show the current Power Sourcing Equipment (PSE) status for the given interface.

	   podl-pse-admin-state
		  This attribute indicates the operational status of PoDL PSE functions, which can  be	modified  using	 the
		  podl-pse-admin-control parameter. It corresponds to IEEE 802.3-2018 30.15.1.1.2 (aPoDLPSEAdminState), with
		  potential values being enabled, disabled

	   podl-pse-power-detection-status
		  This	attribute  indicates  the  power detection status of the PoDL PSE. The status depend on internal PSE
		  state machine and automatic PD classification support.  It  corresponds  to  IEEE  802.3-2018	 30.15.1.1.3
		  (aPoDLPSEPowerDetectionStatus)  with	potential values being disabled, searching, delivering power, sleep,
		  idle, error

	   c33-pse-admin-state
		  This attribute indicates the operational status of c33 PSE functions, which  can  be	modified  using	 the
		  c33-pse-admin-control	 parameter.  It corresponds to IEEE 802.3-2022 30.9.1.1.2 (aPSEAdminState), with po‐
		  tential values being enabled, disabled

	   c33-pse-power-detection-status
		  This attribute indicates the power detection status of the c33 PSE. The  status  depend  on  internal	 PSE
		  state machine and automatic PD classification support. It corresponds to IEEE 802.3-2022 30.9.1.1.5 (aPSE‐
		  PowerDetectionStatus) with potential values being disabled, searching, delivering power, test, fault, oth‐
		  er fault

	   c33-pse-extended-state
		  This attribute indicates the Extended state of the c33 PSE. The extended state correlated with the c33 PSE
		  Extended  Substate  allows to have more detail on the c33 PSE current error state.  It corresponds to IEEE
		  802.3-2022 33.2.4.4 Variables.

	   c33-pse-extended-substate
		  This attribute indicates the Extended substate of the c33 PSE. Correlated with the c33 PSE Extended  state
		  value, it allows to have more detail on the c33 PSE current error state.

	   c33-pse-power-class
		  This	attribute  identifies the power class of the c33 PSE. It depends on the class negotiated between the
		  PSE and the PD. It corresponds to IEEE 802.3-2022 30.9.1.1.8 (aPSEPowerClassification).

	   c33-pse-actual-power
		  This attribute identifies the actual power drawn by the c33 PSE. It  corresponds  to	``IEEE	802.3-2022``
		  30.9.1.1.23 (aPSEActualPower). Actual power is reported in mW.

	   c33-pse-available-power-limit
		  This attribute identifies the configured c33 PSE power limit in mW.

	   c33-pse-power-limit-ranges
		  This	attribute  specifies the allowed power limit ranges in mW for configuring the c33-pse-avail-pw-limit
		  parameter. It defines the valid power levels that can be assigned to the c33 PSE in  compliance  with	 the
		  c33 standard.

	   power-domain-index
		  Reports the index of the PSE power domain the port belongs to. Every port belongs to exactly one power do‐
		  main. Port priorities are defined within that power domain.

		  Each	power  domain  may have its own maximum budget (e.g., 100 W per domain) in addition to a system-wide
		  budget (e.g., 200 W overall).	 Domain limits are enforced first: if a single domain  reaches	its  budget,
		  only ports in that domain are affected. The system-wide budget is enforced across all domains.

	   priority-max
		  Reports the maximum configurable port priority value within the reported power domain. The valid range for
		  prio is 0 to priority-max (inclusive).

	   priority
		  Reports  the currently configured port priority within the reported power domain. Lower numeric values in‐
		  dicate higher priority: 0 is the highest priority.

       --set-pse
	      Set Power Sourcing Equipment (PSE) parameters.

	   podl-pse-admin-control  enable|disable
		  This parameter manages PoDL PSE Admin operations  in	accordance  with  the  IEEE  802.3-2018	 30.15.1.2.1
		  (acPoDLPSEAdminControl) specification.

	   c33-pse-admin-control  enable|disable
		  This	parameter  manages  c33	 PSE  Admin  operations	 in  accordance	 with the IEEE 802.3-2022 30.9.1.2.1
		  (acPSEAdminControl) specification.

	   c33-pse-avail-pw-limit  N
		  This parameter manages c33 PSE Available Power Limit	in  mW,	 in  accordance	 with  the  IEEE  802.3-2022
		  33.2.4.4 Variables (pse_available_power) specification.

	   prio	 N
		  Set  the  port priority, scoped to the port's power domain as reported by power-domain-index. Lower values
		  indicate higher priority; 0 is the highest. The valid range is 0 to the priority-max reported	 by  --show-
		  pse.

		  When	a  single  domain  exceeds its budget, ports in that domain are powered up/down by priority (highest
		  first for power-up; lowest shed first).

       --flash-module-firmware
	      Flash the transceiver module's firmware. The firmware update process is composed	from  three  logical  steps.
	      Downloading  a firmware image to the transceiver module, running the image and committing the image so that it
	      is run upon reset. When flash command is given, the firmware update process is performed in  its	entirety  in
	      that order.

	   file FILE
		  Specifies  the  filename of the transceiver module firmware image. The firmware must first be installed in
		  one of  the  directories  where  the	kernel	firmware  loader  or  firmware	agent  will  look,  such  as
		  /lib/firmware. The firmware image is downloaded to the transceiver module, validated, run and committed.

	   pass PASS
		  Optional transceiver module password that might be required as part of the transceiver module firmware up‐
		  date process.

       --show-phys
	      Show the PHY devices attached to an interface, and the way they link together.

	   phy_index
		  The PHY's index, that identifies it within the network interface. If the interface has multiple PHYs, they
		  will	each  have  a  unique index on that interface. This index can then be used for commands that targets
		  PHYs.

	   drvname
		  The name of the driver bound to this PHY device.

	   name	  The PHY's device name, matching the name found in sysfs.

	   downstream_sfp_name
		  If the PHY drives an SFP cage, this field contains the name of the associated SFP bus.

	   upstream_type  mac | phy
		  Indicates the nature of the device the PHY is attached to.

	   upstream_index
		  If the PHY's upstream_type is phy , this field indicates the phy_index of the upstream phy.

	   upstream_sfp_name
		  If the PHY is withing an SFP/SFF module, this field contains the name of the upstream SFP bus.

BUGS
       Not supported (in part or whole) on all network drivers.

AUTHOR
       ethtool was written by David Miller.

       Modifications by Jeff Garzik, Tim Hockin, Jakub Jelinek, Andre Majorel, Eli Kupermann,  Scott  Feldman,	Andi  Kleen,
       Alexander Duyck, Sucheta Chakraborty, Jesse Brandeburg, Ben Hutchings, Scott Branden.

AVAILABILITY
       ethtool is available from http://www.kernel.org/pub/software/network/ethtool/

Ethtool version 6.19					  Feb 2026						  ETHTOOL(8)